Dahua CAT6 Cable Outdoor 305m PFM920-6U ( black)

210.92 ex. VAT | 251.00 inc. VAT

Availability: In Stock

SKU: 25416.

  • Type: Cat6
  • Cable Type: UTP
  • Conductor: Pure Copper
  • Environment: Outdoor
  • Length: 305m
  • Colour: Black

Product Description

 Datasheet

 

  • 305m (1000 ft)/carton outdoor UTP CAT6, power over Ethernet, compatible with one cable
  • High-purity Oxygen-Free Copper conductor material
  • Customized MDPE outer sheath; meet ANSI/TIA 568-C.2 flame retardant class certified
  • Environmentally friendly and all materials used are RoHS compliant

Conductor

  • Material : Oxygen free copper (99.97% purity)
  • Diameter : 0.57 mm ± 0.02 mm
  • Wire Gauge : 23AWG

Insulation

  • Material : HDPE
  • Min. Average Thickness : 0.21 mm
  • Diameter : 1.02 mm ± 0.06 mm
  • Color : 8-core, Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Rip Cord

  • Material : Polyester
  • Specification : 500D

Separator

  • Material : PE
  • Dimension : Translucent 4.5 × 0.4 mm

Wrap

  • Material : Polyester tape (transparent)
  • Dimension : W: 25mm±2mm*T: 0.026mm±0.02mm

Sheath

  • Material : MDPE
  • Min. Average Thickness : 0.7 mm
  • Diameter : 6.2 mm ± 0.4 mm
  • Color : Black

Electrical

  • Max. DC Resistance of a Single Conductor : 7.35Ω/100 m
  • Min. Insulation Resistance : 5000MΩ·km
  • Max. DC Resistance Unbalance : 2% (pair intra), 4% (pairs inter)
  • Dielectric Strength : No breakdown with 1KV DC for 1 min

Transmission

  • Characteristic Impedance  : 100 ± 15Ω
  • Near End Cross Talk : ≥39.30 dB/100 m@250 MHz
  • Max. Attenuation : 32.8 dB/100 m@250 MHz
  • Return Loss : ≥17.3 dB/100 m@250 MHz

Mechanical

  • Tensile Strength : Sheath≥12 MPa, insulation≥16 MPa
  • Elongation at Break : Sheath≥350%, insulation≥300%
  • Installation Bending Radius : >8 times of outer cable diameter
  • Conductor Elongation at Break : ≥15%

Environmental

  • Shrinkage of Insulation : ≤5%
  • Color Migration Resistance of Insulation : No migration
  • Low Temperature Bending Test : No cracking after the test
  • Heat Shock Test : No cracking after the test
  • Operation Temperature : –20°C to +60°C (–4°F to 140°F)
  • Installation Temperature : 0°C to +50°C (32°F to 122°F)
  • Storage Temperature and Humidity : –10°C to +40°C (14°F to 104°F), <60% (RH)

Packaging

  • Length : 305m ± 2 m
  • Packaging Dimensions : 476mm × 476 mm × 222 mm (L × W × H)
  • Net Weight : 11.7kg±0.6kg
  • Gross Weight : 12.7kg±0.6kg

Executive Standard

  • Executive Standard : ANSI/TIA 568-C.2

Stats: 203 queries in 0.814 seconds.